帶閥帶導(dǎo)桿氣缸 MVGQ
MVGQL32-S4659-50 |
MVGQL40-25-Y7BAL |
MVGQL50-100 |
MVGQL63-50-Z73 |
MVGQL80-50 |
MVGQL80-S4097-35 |
MVGQL80-S4097-50 |
MVGQM12-10 |
MVGQM12-20 |
MVGQM12-50 |
MVGQM20-100-Z73L |
MVGQM20-40 |
MVGQM20-50 |
MVGQM25-50-Z73S |
MVGQM32-50 |
MVGQM50-100-Z73L |
MVGQM63-50-Z73 |
MVGQM80-30-Z73 |
MVV5Q11-12C4FU0/Z-2870 |
MXF10-40-X288 |
MXF10-40-X288A |
MXF10-40-X308 |
MXF10-40-X308A |
MXF12-20 |
MXF12-20-A90 |
MXF12-20-A90L |
MXF12-20-A93 |
MXF12-20-A93L |
MXF12-20-A93LS |
MXF12-20-A93S |
MXF12-20-A93V |
MXF12-20-A93VL |
MXF12-20-A96 |
MXF12-20-A96L |
MXF12-20-A96VL |
MXF12-20-F9B |
MXF12-20-F9BL |
MXF12-20-F9BLS |
MXF12-20-F9BL-X351 |
MXF12-20-F9BS |
MXF12-20-F9BV |
MXF12-20-F9BVL |
MXF12-20-F9BWL |
MXF12-20-F9BWS |
MXF12-20-F9N |
MXF12-20-F9NL |
MXF12-20-F9NLS |
MXF12-20-F9NS |
MXF12-20-F9NV |
MXF12-20-F9NVL |
MXF12-20-F9NW |
MXF12-20-F9NWL |
MXF12-20-F9NWLS |
MXF12-20-M9BL |
MXF12-20-M9BV |
MXF12-20-M9NL |
MXF12-20-X39 |
MXF12-20-X6 |
MXF12-30 |
MXF12-30-A90 |
MXF12-30-A90L |
MXF12-30-A93 |
MXF12-30-A93L |
氣動元件的流量特性,是指氣動元件進(jìn)出口兩端的壓力降與通過該元件的流量之間的關(guān)系。
表述氣動元件流量特性的方法主要有以下幾種:
1、流通能力Cv值和Kv值
2、額定流量下的壓力降
3、流量-壓力降特性曲線
4、不可壓縮狀態(tài)下的有效截面積A值
5、有效截面積S值
6、流量系數(shù)Cd
7、聲速流導(dǎo)C值與臨界壓力比b值
8、壅塞狀態(tài)下的有效截面積S值和臨界壓力比b值
Cv值:被測元件全開,元件兩端壓差△p.=1bf/in2(1lbf/in2=6.89kPa),溫度為60℉(15.5℃)的水,通過元件的流量為qv,單位為USgas/min(USgas/min=3.785L/min),則流通能力Cv值為
Cv=qv*[ρ*△p0/(ρ0*△p)]^0.5
式中:
Cv:流通能力,USgas/min
qv:實測水的流量,USgas/min
ρ:實測水的密度,g/cm3;
ρ0:60℉下水的密度,ρ0=1g/cm3;
△p.=p1-p2。p1和p2是被測元件上下游的壓力差,lbf/in2。
Kv值:被測元件全開,元件兩端壓差△p.==0.1MPa,流體密度ρ=1g/cm3時;通過元件的流量為qv(m3/h),則流通能力Kv值為
Kv=qv*[ρ*△p0/(ρ0*△p)]^0.5
式中:
Kv:流通能力,m3/h;
ρ:實測流體密度,g/cm3;
△p.=p1-p2。p1和p2是被測元件上下游的壓力差,MPa。
聯(lián)系我們
上海達(dá)朋自動化控制設(shè)備有限公司 公司地址:深圳市龍華區(qū)觀湖街道環(huán)觀南路94號 技術(shù)支持:化工儀器網(wǎng)掃一掃 更多精彩
微信二維碼